Paloma
Specifications
Indoor
Outdoor
Direct Vent
Natural Gas Model Number Wholesale
PH-20R IFSN
PH-20R OFN
PH-20R DVSN
Natural Gas Model NumberRetail
N/A
N/A
N/A
LP Gas Model NumberWholesale
PH-20R IFSP
PH-20R OFP
PH-20R DVSP
LP Gas Model Number Retail
N/A
N/A
N/A
Rated Gas Input(BTUs/Hr.)
21,600 (minimum)
145,000 Nat. / 141,0000 LP (maximum) Modulating
21,600 (minimum)
141,0000 (maximum) Modulating
21,600 (minimum)
141,0000 Nat. / 135,000 LP (maximum) Modulating
Dimensions (Inches)
13-3/4 (W) x 20-1/2 (H) x 5-5/6 (D)
Empty Net Weight (lbs.)
35
Working Water Pressure
14 psi (minimum); 150 psi (maximum)
Water Flow Rate
0.66 GPM (minimum) 5.3 GPM (maximum) (23 psi)
Gas Connection
3/4" NPT Female (With Supplied Gas Shutoff Valve)
Water Connection
3/4" NPT Male
Vent Size
3" Special Venting
N/A (Outdoor Installation)
3"/5" Concentric Category III stainless steel venting required
Efficiency Rating
82%
Energy Factor
0.82
Electrical Rating
120 VAC/60 Hz, Less than 2 Amps

Factory-set maximum temperature is 120 degrees F
For installations above 3,280 feet, the connector to the PC board must be replaced. Consult factory or your supplier for details.


The ICAD is a sophisticated system that monitors and optimizes combustion in the firing chamber, providing protection against Carbon Monoxide.
Learn more.
Sae up to $300 Home Energy Improvement Tax Credit
Everyone claims that their product is greener but few take the next step. Paloma is taking that step; we're seeking a solution to a serious and difficult issue. Paloma is ready to meet the challenge.
Learn more.

With any water heater, the trick is to make certain that you don't run out of hot water. View a complete comparison of features and benefits. Learn more.
Copyright © 2005 - 2008 Paloma Industries, Inc. All rights reserved. | Privacy | Site Map